Quantity: 0 pcs |
Material: Steel |
Process Mode: Filtration + UV principal |
Standard: IMO MEPC.279(70) |
Certificate: ABS |
250m³ Ballast Water Management System
Ballast water management system is a key international measurement for environmental protection that aims to stop the spread of potential invasive aquatic species in ships'ballast water enters into force.
Technical Conditions
Ballast pump capacity | 250m³/hr |
Humidity range | 0~90% |
Air condition | salt air(Ocean atmosphere) |
Environment temperature | 0~55℃ |
Seawater temperature | 0~35℃ |
Salt condition | ≥3 PSU |
Static condition | all directions≤22.5° |
Dynamic condition | all directions≤22.5° |
Voltage floating | ±10% |
Instantaneous voltage floating | ±20% |
Frequency floating | ±5% |
Instantaneous frequency floating | ±10% |
Power supply | 440V, 60Hz, 3Φ |
outlet of EDU to main ballasting pipe | Plastic coated steel pipe |
Outlet of ANU to main ballasting pipe | SS316 |
Ventilation system pipe | SCH.80 seamless steel tube or to be compliance with requirement of class |
Working Process